  Datasheet File OCR Text:
 TFS208H.doc
version 1.3
05.02.2003
VI TELEFILTER
Measurement Condition
Ambient temperature: Input power level: Source impedance: Load impedance: Terminating impedances: *) 23 0 200 50 input: output:
Filter Specification
TFS 208 H
1/5
C dBm balanced single ended 410 // -10,3 pF 264 // -12,7 pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 208H is the attenuation at 208 MHz. Reference for the echo response
attenuation is the main time response lobe, the reference time is defined as t0. The nominal frequency fN is fixed at 208 MHz without tolerance. The given values for the relative attenuation a rel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Absolute attenuation within fN Nominal frequency Pass band ripple fN ..... fN fN 0,1 MHz ... fN fN 0,2 MHz ... fN 1 dB-bandwidth Relative attenuation fN ... fN fN 1,2 1,8 fN fN 6 fN - 13 fN + 13 MHz ... MHz ... MHz ... MHz ... MHz ... arel 0,5 MHz MHz MHz MHz MHz MHz arel
fN 0,1 MHz
typ. Value
7 dB
Limit
6 ... 8,5 dB 208 MHz
0,1 MHz 0,2 MHz 0,5 MHz
0,05 dB 0,1 dB 0,6 dB 1180 kHz
max. max. max.
0,25 dB 0,5 dB 1 dB kHz
min. 1000
15 28 50 65 65 dB dB dB dB dB
max. min. min. min. min. min.
1 9 25 35 50 50
dB dB dB dB dB dB
fN 1,8 fN 6 fN 13 fN - 198 fN + 242
Echo response attenuation t0 + 1 s t0 + 2 s t0 + 3 s t0 + 4 s t0 + 5 s Group delay Group delay ripple within fN Input power level VSWR IP3 **) Operating temperature range Storage temperature range
within fN
35 45 55 70 80 at fN
0,5 MHz
dB dB dB dB dB ns ns -
min. min. min. min. min.
20 30 40 40 50
dB dB dB dB dB ns ns dBm
525 100
max. 750 max. 150 max. + 10 max. min. 2:1 60
0,5 MHz
18 65
dB dBm 2
dBm
- 10 C ... + 85 C - 40 C ... + 125 C C
Temperature coefficient of frequency Frequency inversion temperature
TCf ***
-0,036 ppm/K 15
T0
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) fin,1=208MHz; fin,2=208,1MHz; Pin=4dBm+loss @fN; fout,1=207,9MHz; fout,2=208,2MHz; then P out <-56dBm ***) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
generated: checked / approved:
______________________________________________________________________________________________________ TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS208H.doc
version 1.3
05.02.2003
VI TELEFILTER
Construction and pin configuration
(all dimensions in mm)
Filter Specification
TFS 208 H
2/5
8 9 10 1
9,3 Max. 6 7 5 4 3
Date code
TFS 208H
R06
2
1 2 3 4 5 6 7 8 9 10
ground ground ground output output rf return ground ground ground input input
2,54 0,12,54 0,1 0,10 2 3 1 10 9 8 7 0,8 7,1 6 4 5
date code: N P R
year + week 2001 2002 2003
....
....
matching circuit: input 200
balanced driven / output 50
single ended
LB-IN L1 C1
9
4
OUT L3 C2
SAW
10 5
1:4
L2
1,2,3,6,7,8
______________________________________________________________________________________________________ TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS208H.doc
version 1.3
05.02.2003
VI TELEFILTER
Stability Characteristics
Filter Specification
TFS 208 H
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer
Tape (all dim ensions in mm) W Po Do E F : : : : : 16 4 0,3 0,1
3000 min 300 mm min 500 mm min 300 mm
EMBOSSED CARR IER TAPE
Do
Po
P2
1,5 + 0,1 1,75 0,1 7,5 0,1 0,60 2 0,1 8 0,1 1,5 5,30 0,1 9,70 0,1 13,5 0,1
CT Bo
E Ao F W
G (min) : P2 : P1 : D1(min) : Ao : Bo : CT :
D1
G
P1
COVER TAPE
W2
Reel (all dimensions in mm): A : 330 16,40 +2,0 22,4 50 13,0 0,5/-0.2
A C N
W1 : W2 (max) : N (min) C : :
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
______________________________________________________________________________________________________ TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS208H.doc
version 1.3
05.02.2003
VI TELEFILTER
Air reflow temperature conditions
Filter Specification
TFS 208 H
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
______________________________________________________________________________________________________ TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS208H.doc
version 1.3
05.02.2003
VI TELEFILTER
History
Version Reason of Changes
Filter Specification
TFS 208 H
5/5
Name
Date
Development specification 1.0 1.1 generation of development specification Chilla 17.07.2002 25.09.2002
terminating impedance (preliminary values) and typical values of relative attenuation Pfeiffer added 1 dB-bandwidth added terminating impedance and typical values of relative attenuation changed Pfeiffer Pfeiffer
1.2 1.3
05.11.2002 05.02.2003
______________________________________________________________________________________________________ TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS208H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X